Solar (PV) DC cable
4 mm²Single-core solar cable (PV1-F, UV-resistant)
- Red (+)33 m
- Black (−)33 m
Design current 21.7 A · voltage drop 1.14%. 2 strings × 15 m run, each on its own pair.
Tell us what you want to power and where. Get the inverter, batteries, panels, cable sizes and lengths, breakers and a complete shopping list for your installation.
The battery carries your load through an outage of the length you choose; solar recharges it.
Longer life, deeper discharge, no maintenance.
Typical annual average for South-West. The north gets more sun than the coast, so it needs fewer panels.
Pre-filled with typical values for a 550 W panel. For an exact design, copy the figures from your panel and inverter datasheets.
Sizes the inverter, cables and breakers for extra load now, so you can add panels and batteries later without replacing them. This inverter leaves room for about 414 W more running load.
Measure the one-way cable route — cable sizes and the lengths to buy depend on it.
Your results
None of this design's main equipment exactly matches a product listed in our shop right now, so everything is priced in your quotation.
Hybrid inverter
7.5 kVA, 48 V battery, single-phase output, PV input ≥ 472 V
Solar panels
550 W (2 × 9 in series)
Battery modules
48V 100Ah lithium (5.12 kWh) — 1 in series × 6 parallel = 30.72 kWh @ 48 V
Battery interconnects / busbar
Matched to the battery cable size
Solar (PV) DC cable — Red (+)
4 mm² · Single-core solar cable (PV1-F, UV-resistant)
Solar (PV) DC cable — Black (−)
4 mm² · Single-core solar cable (PV1-F, UV-resistant)
Battery cable — Red (+)
35 mm² · Flexible single-core battery cable with crimped lugs
Battery cable — Black (−)
35 mm² · Flexible single-core battery cable with crimped lugs
AC output cable (inverter → distribution board) — 3-core
10 mm² · 3-core (L, N, E) or singles in conduit
Earth cable — Green/yellow
10 mm² · Green/yellow single-core
PV DC isolator / breaker
40 A, 500 V DC
DC surge protection device (SPD), Type 2
500 V DC PV-rated
Battery DC breaker / fuse
200 A, 250 V DC
AC output breaker (MCB/MCCB)
50 A, 2-pole
AC surge protection device (SPD), Type 2
1-phase + N, 275 V
Changeover switch (manual or ATS)
50 A, 2-pole
Earth rod with clamp
Copper-bonded, 1.2 m or longer
MC4 connector pairs
Matched to the PV cable size
Battery cable lugs
35 mm² copper, crimped
Mounting rails
2 rows of 9 panels, portrait
Mid clamps
Panel-to-panel
End clamps
Row ends
Roof hooks / L-feet
≈ every 1.2 m of rail
Conduit / trunking
For DC and AC runs
Copper cable sized for current rating and voltage drop (PV & AC ≤ 3 %, battery ≤ 1 %), with 10 % extra for routing.
Single-core solar cable (PV1-F, UV-resistant)
Design current 21.7 A · voltage drop 1.14%. 2 strings × 15 m run, each on its own pair.
Flexible single-core battery cable with crimped lugs
Design current 169.8 A · voltage drop 0.91%. Keep this run as short as possible; module interconnects usually come with lithium batteries.
3-core (L, N, E) or singles in conduit
Design current 40.8 A · voltage drop 0.8%.
Green/yellow single-core
Bonds the inverter, panel frames and mounting to the earth rod.
PV DC isolator / breaker
Between the array and the inverter; must be DC-rated.
DC surge protection device (SPD), Type 2
Battery DC breaker / fuse
As close to the battery as possible.
AC output breaker (MCB/MCCB)
AC surge protection device (SPD), Type 2
Changeover switch (manual or ATS)
For grid / generator input.
Earth rod with clamp
Use your own figures — fuel prices change, so we don’t assume them.